Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Ann Intern Med ; 176(9): 1209-1220, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37639719

RESUMO

BACKGROUND: Artificial intelligence computer-aided detection (CADe) of colorectal neoplasia during colonoscopy may increase adenoma detection rates (ADRs) and reduce adenoma miss rates, but it may increase overdiagnosis and overtreatment of nonneoplastic polyps. PURPOSE: To quantify the benefits and harms of CADe in randomized trials. DESIGN: Systematic review and meta-analysis. (PROSPERO: CRD42022293181). DATA SOURCES: Medline, Embase, and Scopus databases through February 2023. STUDY SELECTION: Randomized trials comparing CADe-assisted with standard colonoscopy for polyp and cancer detection. DATA EXTRACTION: Adenoma detection rate (proportion of patients with ≥1 adenoma), number of adenomas detected per colonoscopy, advanced adenoma (≥10 mm with high-grade dysplasia and villous histology), number of serrated lesions per colonoscopy, and adenoma miss rate were extracted as benefit outcomes. Number of polypectomies for nonneoplastic lesions and withdrawal time were extracted as harm outcomes. For each outcome, studies were pooled using a random-effects model. Certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. DATA SYNTHESIS: Twenty-one randomized trials on 18 232 patients were included. The ADR was higher in the CADe group than in the standard colonoscopy group (44.0% vs. 35.9%; relative risk, 1.24 [95% CI, 1.16 to 1.33]; low-certainty evidence), corresponding to a 55% (risk ratio, 0.45 [CI, 0.35 to 0.58]) relative reduction in miss rate (moderate-certainty evidence). More nonneoplastic polyps were removed in the CADe than the standard group (0.52 vs. 0.34 per colonoscopy; mean difference [MD], 0.18 polypectomy [CI, 0.11 to 0.26 polypectomy]; low-certainty evidence). Mean inspection time increased only marginally with CADe (MD, 0.47 minute [CI, 0.23 to 0.72 minute]; moderate-certainty evidence). LIMITATIONS: This review focused on surrogates of patient-important outcomes. Most patients, however, may consider cancer incidence and cancer-related mortality important outcomes. The effect of CADe on such patient-important outcomes remains unclear. CONCLUSION: The use of CADe for polyp detection during colonoscopy results in increased detection of adenomas but not advanced adenomas and in higher rates of unnecessary removal of nonneoplastic polyps. PRIMARY FUNDING SOURCE: European Commission Horizon 2020 Marie Sklodowska-Curie Individual Fellowship.


Assuntos
Inteligência Artificial , Neoplasias Colorretais , Humanos , Neoplasias Colorretais/diagnóstico , Computadores , Colonoscopia , Bases de Dados Factuais
2.
Am J Gastroenterol ; 118(12): 2276-2279, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37410934

RESUMO

INTRODUCTION: Artificial intelligence chatbots could serve as an information resource for patients and a tool for clinicians. Their ability to respond appropriately to questions regarding gastroesophageal reflux disease is unknown. METHODS: Twenty-three prompts regarding gastroesophageal reflux disease management were submitted to ChatGPT, and responses were rated by 3 gastroenterologists and 8 patients. RESULTS: ChatGPT provided largely appropriate responses (91.3%), although with some inappropriateness (8.7%) and inconsistency. Most responses (78.3%) contained at least some specific guidance. Patients considered this a useful tool (100%). DISCUSSION: ChatGPT's performance demonstrates the potential for this technology in health care, although also its limitations in its current state.


Assuntos
Gastroenterologistas , Refluxo Gastroesofágico , Humanos , Inteligência Artificial , Software , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/terapia
3.
Scand J Gastroenterol ; 58(6): 664-670, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36519564

RESUMO

OBJECTIVES: Meticulous inspection of the mucosa during colonoscopy, represents a lengthier withdrawal time, but has been shown to increase adenoma detection rate (ADR). We investigated if artificial intelligence-aided speed monitoring can improve suboptimal withdrawal time. METHODS: We evaluated the implementation of a computer-aided speed monitoring device during colonoscopy at a large academic endoscopy center. After informed consent, patients ≥18 years undergoing colonoscopy between 5 March and 29 April 2021 were examined without the use of the speedometer, and with the speedometer between 29 April and 30 June 2021. All colonoscopies were recorded, and withdrawal time was assessed based on the recordings in a blinded fashion. We compared mean withdrawal time, percentage of withdrawal time ≥6 min, and ADR with and without the speedometer. RESULTS: One hundred sixty-six patients in each group were eligible for analyses. Mean withdrawal time was 9 min and 6.6 s (95% CI: 8 min and 34.8 s to 9 min and 39 s) without the use of the speedometer, and 9 min and 9 s (95% CI: 8 min and 45 s to 9 min and 33.6 s) with the speedometer; difference 2.3 s (95% CI: -42.3-37.7, p = 0.91). The ADRs were 45.2% (95% CI: 37.6-52.8) without the speedometer as compared to 45.8% (95% CI: 38.2-53.4) with the speedometer (p = 0.91). The proportion of colonoscopies with withdrawal time ≥6 min without the speedometer was 85.5% (95% CI: 80.2-90.9) versus 86.7% (95% CI: 81.6-91.9) with the speedometer (p = 0.75). CONCLUSIONS: Use of speed monitoring during withdrawal did not increase withdrawal time or ADR in colonoscopy. CLINICALTRIALS.GOV IDENTIFIER: NCT04710251.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Adenoma/diagnóstico , Inteligência Artificial , Colonoscopia , Neoplasias Colorretais/diagnóstico , Fatores de Tempo , Adulto
4.
Gastrointest Endosc ; 97(3): 394-406.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36402203

RESUMO

BACKGROUND AND AIMS: Transoral incisionless fundoplication (TIF) using the EsophyX device (EndoGastric Solutions, Inc, Redmond, Wash, USA) is a minimally invasive endoscopic fundoplication technique. Our study aimed to assess the efficacy of TIF for atypical GERD symptoms in patients with chronic or refractory GERD. METHODS: A systematic search of 4 major databases was performed. All original studies assessing atypical GERD using a validated symptom questionnaire (the reflux symptom index [RSI]) were included. The RSI score was assessed before and after TIF at a 6- and 12-month follow-up. Data on technical success rate, adverse events, proton pump inhibitor (PPI) use, and patient satisfaction were also collected. Only TIF procedures currently in practice using the EsophyX device (ie, TIF 2.0) and TIF with concomitant hiatal hernia repair were included in the review. RESULTS: Ten studies (564 patients) were included. At the 6- and 12- month follow-up, there was a mean reduction of 15.72 (95% confidence interval, 12.15-19.29) and 14.73 (95% confidence interval, 11.74-17.72) points, respectively, in the RSI score post-TIF, with a technical success rate of 99.5% and a pooled adverse event rate of 1%. At both time intervals, more than two-thirds of the patients were satisfied with their health condition and roughly three-fourths of the patients were off daily PPIs. CONCLUSIONS: Our study shows that TIF using the EsophyX device is safe and effective in reducing atypical GERD symptoms at 6 and 12 months of follow-up. It improves patient-centered outcomes and can be a minimally invasive therapeutic option for patients suffering from atypical GERD symptoms on chronic medical therapy.


Assuntos
Fundoplicatura , Refluxo Gastroesofágico , Humanos , Fundoplicatura/métodos , Resultado do Tratamento , Refluxo Gastroesofágico/tratamento farmacológico , Satisfação do Paciente , Inibidores da Bomba de Prótons/uso terapêutico
5.
Clin Transl Gastroenterol ; 14(3): e00552, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36563088

RESUMO

INTRODUCTION: Opioid-induced esophageal dysfunction has been described with characteristic manometric patterns, but the population burden of dysphagia attributable to opioid use remains unclear. METHODS: The National Ambulatory Medical Care Survey from 2008 to 2018 was used to assess the relationship between opioid use and outpatient visits for dysphagia. RESULTS: After controlling for potential confounders, there were no significant difference in ambulatory visits for dysphagia between opioid users and nonusers (adjusted odds ratio = 0.98, confidence interval: 0.59-1.65). DISCUSSION: No correlation between opioid use and ambulatory visits for dysphagia was found in a nationwide sample. Opioid-related manometric changes may be clinically relevant only in a small proportion of patients.


Assuntos
Analgésicos Opioides , Transtornos de Deglutição , Humanos , Analgésicos Opioides/efeitos adversos , Pacientes Ambulatoriais , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/epidemiologia , Pesquisas sobre Atenção à Saúde , Razão de Chances
6.
Am J Gastroenterol ; 118(4): 692-701, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36563308

RESUMO

INTRODUCTION: Nocebo effects are believed to influence the rate of reported adverse events (AE) and subject withdrawal in both the treatment and placebo groups of randomized clinical trials (RCT). Neuromodulators are commonly prescribed to treat disorders of gut-brain interaction (DGBI), but adherence to these medications is often limited by side effects such as headache, dry mouth, fatigue, and altered bowel habits. We performed a systematic review and meta-analysis to assess the proportion and risk difference of patients who experienced side effects leading to withdrawal in the placebo arm vs the treatment arm of RCT of neuromodulators for DGBI. We also sought to estimate the risk of developing any AE in the placebo arm of these studies and the rate of specific individual AEs. METHODS: We searched MEDLINE, Embase, Web of Science Core Collection, and the Cochrane Central Register of Controlled Trials Searches to identify RCT that included terms for DGBI and for commonly prescribed neuromodulators. We calculated pooled proportions of patients experiencing an AE leading to withdrawal in the active treatment group vs the placebo group with 95% confidence intervals (CI), the pooled proportions of patients experiencing any AE, the pooled proportions of patients experiencing specific AE such as dizziness and headache, the pooled proportions of patients experiencing severe AE, and corresponding pooled risk differences with 95% CI. RESULTS: There were 30 RCT included representing 2,284 patients with DGBI. Twenty-seven RCT reported data on AE leading to withdrawal. The pooled proportion of total patients with AE leading to withdrawal in the placebo group was 4% (95% CI 0.02-0.04). The pooled proportion of patients with AE leading to withdrawal who received neuromodulators was 9% (95% CI 0.06-0.13). In the 12 studies reporting data on patients experiencing at least 1 AE, the pooled proportion of patients experiencing any AE in the placebo group was 18% (95% CI 0.08-0.30), compared with 43% (95% CI 0.24-0.63) in the neuromodulator group. Thus, approximately 44% of the rate of withdrawal (0.04/0.09) and 42% of the rate reporting any side effects (0.18/0.43) in the neuromodulator group may be attributed to nocebo effects in the right context. Subgroup analysis by sex, medication class, risk of bias, and specific DGBI revealed differing withdrawal rates. There was no statistically significant difference in patients experiencing individual AE of dizziness, headache, or diarrhea. Rates of dry mouth, fatigue, and constipation were higher in treatment groups compared with those in placebo groups. DISCUSSION: Patients with DGBI in RCT randomized to placebo groups frequently experience AE and AE that lead to withdrawal consistent with a strong nocebo effect. Nonspecific AE such as dizziness, headaches, and diarrhea occurred similarly in patients receiving placebo compared with those receiving neuromodulators.


Assuntos
Tontura , Efeito Nocebo , Humanos , Encéfalo , Diarreia , Cefaleia/induzido quimicamente , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Clin Gastroenterol Hepatol ; 21(4): 949-959.e2, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36038128

RESUMO

BACKGROUND AND AIMS: Artificial intelligence (AI) tools aimed at improving polyp detection have been shown to increase the adenoma detection rate during colonoscopy. However, it is unknown how increased polyp detection rates by AI affect the burden of patient surveillance after polyp removal. METHODS: We conducted a pooled analysis of 9 randomized controlled trials (5 in China, 2 in Italy, 1 in Japan, and 1 in the United States) comparing colonoscopy with or without AI detection aids. The primary outcome was the proportion of patients recommended to undergo intensive surveillance (ie, 3-year interval). We analyzed intervals for AI and non-AI colonoscopies for the U.S. and European recommendations separately. We estimated proportions by calculating relative risks using the Mantel-Haenszel method. RESULTS: A total of 5796 patients (51% male, mean 53 years of age) were included; 2894 underwent AI-assisted colonoscopy and 2902 non-AI colonoscopy. When following U.S. guidelines, the proportion of patients recommended intensive surveillance increased from 8.4% (95% CI, 7.4%-9.5%) in the non-AI group to 11.3% (95% CI, 10.2%-12.6%) in the AI group (absolute difference, 2.9% [95% CI, 1.4%-4.4%]; risk ratio, 1.35 [95% CI, 1.16-1.57]). When following European guidelines, it increased from 6.1% (95% CI, 5.3%-7.0%) to 7.4% (95% CI, 6.5%-8.4%) (absolute difference, 1.3% [95% CI, 0.01%-2.6%]; risk ratio, 1.22 [95% CI, 1.01-1.47]). CONCLUSIONS: The use of AI during colonoscopy increased the proportion of patients requiring intensive colonoscopy surveillance by approximately 35% in the United States and 20% in Europe (absolute increases of 2.9% and 1.3%, respectively). While this may contribute to improved cancer prevention, it significantly adds patient burden and healthcare costs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Masculino , Feminino , Pólipos do Colo/diagnóstico , Pólipos do Colo/cirurgia , Pólipos do Colo/epidemiologia , Inteligência Artificial , Ensaios Clínicos Controlados Aleatórios como Assunto , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/cirurgia , Adenoma/epidemiologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/epidemiologia
8.
World J Gastrointest Oncol ; 14(5): 989-1001, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35646286

RESUMO

Artificial intelligence (AI) is a quickly expanding field in gastrointestinal endoscopy. Although there are a myriad of applications of AI ranging from identification of bleeding to predicting outcomes in patients with inflammatory bowel disease, a great deal of research has focused on the identification and classification of gastrointestinal malignancies. Several of the initial randomized, prospective trials utilizing AI in clinical medicine have centered on polyp detection during screening colonoscopy. In addition to work focused on colorectal cancer, AI systems have also been applied to gastric, esophageal, pancreatic, and liver cancers. Despite promising results in initial studies, the generalizability of most of these AI systems have not yet been evaluated. In this article we review recent developments in the field of AI applied to gastrointestinal oncology.

9.
Clin Gastroenterol Hepatol ; 20(7): 1499-1507.e4, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34530161

RESUMO

BACKGROUND & AIMS: Artificial intelligence-based computer-aided polyp detection (CADe) systems are intended to address the issue of missed polyps during colonoscopy. The effect of CADe during screening and surveillance colonoscopy has not previously been studied in a United States (U.S.) population. METHODS: We conducted a prospective, multi-center, single-blind randomized tandem colonoscopy study to evaluate a deep-learning based CADe system (EndoScreener, Shanghai Wision AI, China). Patients were enrolled across 4 U.S. academic medical centers from 2019 through 2020. Patients presenting for colorectal cancer screening or surveillance were randomized to CADe colonoscopy first or high-definition white light (HDWL) colonoscopy first, followed immediately by the other procedure in tandem fashion by the same endoscopist. The primary outcome was adenoma miss rate (AMR), and secondary outcomes included sessile serrated lesion (SSL) miss rate and adenomas per colonoscopy (APC). RESULTS: A total of 232 patients entered the study, with 116 patients randomized to undergo CADe colonoscopy first and 116 patients randomized to undergo HDWL colonoscopy first. After the exclusion of 9 patients, the study cohort included 223 patients. AMR was lower in the CADe-first group compared with the HDWL-first group (20.12% [34/169] vs 31.25% [45/144]; odds ratio [OR], 1.8048; 95% confidence interval [CI], 1.0780-3.0217; P = .0247). SSL miss rate was lower in the CADe-first group (7.14% [1/14]) vs the HDWL-first group (42.11% [8/19]; P = .0482). First-pass APC was higher in the CADe-first group (1.19 [standard deviation (SD), 2.03] vs 0.90 [SD, 1.55]; P = .0323). First-pass ADR was 50.44% in the CADe-first group and 43.64 % in the HDWL-first group (P = .3091). CONCLUSION: In this U.S. multicenter tandem colonoscopy randomized controlled trial, we demonstrate a decrease in AMR and SSL miss rate and an increase in first-pass APC with the use of a CADe-system when compared with HDWL colonoscopy alone.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Aprendizado Profundo , Diagnóstico por Computador , Adenoma/diagnóstico , Adenoma/patologia , Inteligência Artificial , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Humanos , Diagnóstico Ausente , Estudos Prospectivos , Método Simples-Cego , Estados Unidos
10.
Dig Endosc ; 34(1): 4-12, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33715244

RESUMO

Gastroenterology has been an early leader in bridging the gap between artificial intelligence (AI) model development and clinical trial validation, and in recent years we have seen the publication of several randomized clinical trials examining the role of AI in gastroenterology. As AI applications for clinical medicine advance rapidly, there is a clear need for guidance surrounding AI-specific study design, evaluation, comparison, analysis and reporting of results. Several initiatives are in the publication or pre-publication phase including AI-specific amendments to minimum reporting guidelines for clinical trials, society task force initiatives aimed at priority use cases and research priorities, and minimum reporting guidelines that guide the reporting of clinical prediction models. In this paper, we examine applications of AI in clinical trials and discuss elements of newly published AI-specific extensions to the Consolidated Standards of Reporting Trials and Standard Protocol Items: Recommendations for Interventional Trials statements that guide clinical trial reporting and development. We then review AI applications at the pre-trial level in both endoscopy and other subfields of gastroenterology and explore areas where further guidance is needed to supplement the current guidance available at the pre-trial level.


Assuntos
Inteligência Artificial , Gastroenterologia , Endoscopia Gastrointestinal , Humanos , Projetos de Pesquisa
12.
Gastrointest Endosc Clin N Am ; 31(4): 743-758, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34538413

RESUMO

Over the past decade, artificial intelligence (AI) has been broadly applied to many aspects of human life, with recent groundbreaking successes in facial recognition, natural language processing, autonomous driving, and medical imaging. Gastroenterology has applied AI to a vast array of clinical problems, and some of the earliest prospective trials examining AI in medicine have been in computer vision applied to endoscopy. Evidence is mounting for 2 broad areas of AI as applied to gastroenterology: computer-aided detection and computer-aided diagnosis.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Diagnóstico por Computador , Diagnóstico por Imagem , Humanos , Estudos Prospectivos
13.
Gastrointest Endosc ; 94(5): 953-958, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34081967

RESUMO

BACKGROUND AND AIMS: Image-guided radiation therapy (IGRT) often relies on EUS-guided fiducial markers. Previously used manually backloaded fiducial needles have multiple potential limitations including safety and efficiency concerns. Our aim was to evaluate the efficacy, feasibility, and safety of EUS-guided placement of gold fiducials using a novel preloaded 22-gauge needle compared with a traditional, backloaded 19-gauge needle. METHODS: This was a single-center comparative cohort study. Patients with pancreatic and hepatobiliary malignancy who underwent EUS-guided fiducial placement (EUS-FP) between October 2014 and February 2018 were included. The main outcome was the technical success of fiducial placement. Secondary outcomes were mean procedure time, fiducial visibility during IGRT, technical success of IGRT delivery, and adverse events. RESULTS: One hundred fourteen patients underwent EUS-FP during the study period. Of these, 111 patients had successful placement of a minimum of 2 fiducials. Fifty-six patients underwent placement using a backloaded 19-gauge needle and 58 patients underwent placement using a 22-gauge preloaded needle. The mean number of fiducials placed successfully at the target site was significantly higher in the 22-gauge group compared with the 19-gauge group (3.53 ± .96 vs 3.11 ± .61, respectively; P = .006). In the 22-gauge group, the clinical goal of placing 4 fiducials was achieved in 78%, compared with 23% in the 19-gauge group (P < .001). In univariate analyses, gender, age, procedure time, tumor size, and location did not influence the number of successfully placed fiducials. Technical success of IGRT with fiducial tracking was high in both the 19-gauge (51/56, 91%) and the 22-gauge group (47/58, 81%; P = .12). CONCLUSIONS: EUS-FP using a preloaded 22-gauge needle is feasible, effective, and safe and allows for a higher number of fiducials placed when compared with the traditional backloaded 19-gauge needle.


Assuntos
Radioterapia Guiada por Imagem , Estudos de Coortes , Endossonografia , Marcadores Fiduciais , Humanos , Agulhas
15.
Gastroenterology ; 160(6): 2212-2213, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33516702
16.
Endoscopy ; 53(9): 937-940, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33137833

RESUMO

BACKGROUND: The occurrence of false-positive alerts is an important outcome measure in computer-aided colon polyp detection (CADe) studies. However, there is no consensus definition of a false positive in clinical trials evaluating CADe in colonoscopy. We aimed to study the diagnostic performance of CADe based on different threshold definitions for false-positive alerts. METHODS: A previously validated CADe system was applied to screening/surveillance colonoscopy videos. Different thresholds for false-positive alerts were defined based on the time an alert box was continuously traced by the system. Primary outcomes were false-positive results and specificity using different threshold definitions of false positive. RESULTS: 62 colonoscopies were analyzed. CADe specificity and accuracy were 93.2 % and 97.8 %, respectively, for a threshold definition of ≥ 0.5 seconds, 98.6 % and 99.5 % for a threshold definition of ≥ 1 second, and 99.8 % and 99.9 % for a threshold definition of ≥ 2 seconds. CONCLUSION: Our analysis demonstrated how different threshold definitions of false positive can impact the reported diagnostic performance of CADe for colon polyp detection.


Assuntos
Benchmarking , Pólipos do Colo , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Computadores , Humanos , Programas de Rastreamento
17.
Endosc Int Open ; 8(10): E1379-E1384, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33015341

RESUMO

Background and study aims Early studies have shown that artificial intelligence (AI) has the potential to augment the performance of gastroenterologists during endoscopy. Our aim was to determine how gastroenterologists view the potential role of AI in gastrointestinal endoscopy. Methods In this cross-sectional study, an online survey was sent to US gastroenterologists. The survey included questions about physician level of training, experience, and practice characteristics and physician perception of AI. Descriptive statistics were used to summarize sentiment about AI. Univariate and multivariate analyses were used to assess whether background information about physicians correlated to their sentiment. Results Surveys were emailed to 330 gastroenterologists nationwide. Between December 2018 and January 2019, 124 physicians (38 %) completed the survey. Eighty-six percent of physicians reported interest in AI-assisted colonoscopy; 84.7 % agreed that computer-assisted polyp detection (CADe) would improve their endoscopic performance. Of the respondents, 57.2 % felt comfortable using computer-aided diagnosis (CADx) to support a "diagnose and leave" strategy for hyperplastic polyps. Multivariate analysis showed that post-fellowship experience of fewer than 15 years was the most important factor in determining whether physicians were likely to believe that CADe would lead to more removed polyps (odds ratio = 5.09; P  = .01). The most common concerns about implementation of AI were cost (75.2 %), operator dependence (62.8 %), and increased procedural time (60.3 %). Conclusions Gastroenterologists have strong interest in the application of AI to colonoscopy, particularly with regard to CADe for polyp detection. The primary concerns were its cost, potential to increase procedural time, and potential to develop operator dependence. Future developments in AI should prioritize mitigation of these concerns.

18.
Endosc Int Open ; 8(10): E1448-E1454, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33043112

RESUMO

Background Colorectal cancer (CRC) is a major public health burden worldwide, and colonoscopy is the most commonly used CRC screening tool. Still, there is variability in adenoma detection rate (ADR) among endoscopists. Recent studies have reported improved ADR using deep learning models trained on videos curated largely from private in-house datasets. Few have focused on the detection of sessile serrated adenomas (SSAs), which are the most challenging target clinically. Methods We identified 23 colonoscopy videos available in the public domain and for which pathology data were provided, totaling 390 minutes of footage. Expert endoscopists annotated segments of video with adenomatous polyps, from which we captured 509 polyp-positive and 6,875 polyp-free frames. Via data augmentation, we generated 15,270 adenomatous polyp-positive images, of which 2,310 were SSAs, and 20,625 polyp-negative images. We used the CNN AlexNet and fine-tuned its parameters using 90 % of the images, before testing its performance on the remaining 10 % of images unseen by the model. Results We trained the model on 32,305 images and tested performance on 3,590 images with the same proportion of SSA, non-SSA polyp-positive, and polyp-negative images. The overall accuracy of the model was 0.86, with a sensitivity of 0.73 and a specificity of 0.96. Positive predictive value was 0.93 and negative predictive value was 0.96. The area under the curve was 0.94. SSAs were detected in 93 % of SSA-positive images. Conclusions Using a relatively small set of publicly-available colonoscopy data, we obtained sizable training and validation sets of endoscopic images using data augmentation, and achieved an excellent performance in adenomatous polyp detection.

20.
Nephrol Dial Transplant ; 35(11): 1865-1877, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830258

RESUMO

BACKGROUND: Tubulointerstitial fibrosis is a powerful predictor of future progression inimmunoglobulin A (IgA) nephropathy (IgAN). Proximal tubular epithelial cells (PTECs), in concert with infiltrating macrophages, are regarded as the agents provocateurs for driving this fibrotic process. However, evidence is now emerging for a contributory role of the distal nephron. The aim of this study was to examine the potential influence of macrophages on collecting duct epithelial cells (CDECs) and their combined role in the progression of IgAN. METHODS: CDECs were cultured with macrophage-conditioned media (MCM) generated from human monocyte cell lines U937 and THP-1 stimulated with or without 100 µg/mL galactose-deficient IgA1. CDECs were analysed for evidence of inflammation and fibrosis. RESULTS: Staining of IgAN biopsies for CD68+ macrophages revealed the presence of macrophages juxtaposed to collecting ducts and within their lumina. CDEC exposed to MCM from IgA1-stimulated THP-1 cells (THP-1-IgA-MCM) exhibited markedly increased expression of neutrophil-associated gelatinase (NGAL) and proinflammatory cytokinesinterleukin (IL)-1ß, tumour necrosis factor-α, IL-6 and IL-8 compared with MCM from non-IgA-stimulated THP-1 cells (THP-1-MCM). U937-IgA-MCM increased fibronectin levels and reduced E-cadherinmRNA expression. THP-1-IgA-MCM-derived exosomes induced similar increases in NGAL and cytokine expression while in cross-over experiments exosomes extracted from IL-1ß-exposed CDEC induced IL-1ß and IL-6 mRNA expression in both sets of macrophages. MiRnome analysis revealed that microRNA (miR)-146a, -155 and -200b exhibited a >2-fold increase in expression in CDEC treated with THP-1-IgA-MCM compared with THP-1-MCM. Enforced miR-146a suppression further enhanced NGAL expression, while ectopic miR-146a over-expression downregulated it. NGAL mRNA and miR-146a were upregulated in the biopsies of patients with progressive IgAN compared with non-progressive IgAN. CONCLUSIONS: Taken together, these data suggest that CDEC-macrophage interactions potentially contribute to the tubulointerstitial fibrosis characteristic of progressive IgAN.


Assuntos
Células Epiteliais/metabolismo , Fibrose/patologia , Glomerulonefrite por IGA/patologia , Inflamação/patologia , Túbulos Renais/metabolismo , Macrófagos/metabolismo , Células Cultivadas , Células Epiteliais/citologia , Células Epiteliais/imunologia , Fibrose/imunologia , Glomerulonefrite por IGA/imunologia , Humanos , Inflamação/imunologia , Interleucina-1beta/metabolismo , Túbulos Renais/citologia , Túbulos Renais/imunologia , Macrófagos/citologia , Macrófagos/imunologia , Fator de Necrose Tumoral alfa/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...